How would you design a campus to recover from a link or switch failure in under a second?

Show the answer

Say this first

Detect fast, have the alternate path ready, and keep the change local. Use routed point-to-point fiber links so a failure is loss of light, detected in milliseconds, and BFD where something sits in between. Build triangles so ECMP already has the second path installed. Summarize at distribution and use stubs so a failure does not trigger work across the network. Avoid STP and FHRP in the failover path where possible, and use NSF/SSO on dual-supervisor chassis. Then prove it by pulling links under load.

Go deeper

1. Detection

  • Direct routed links between switches. When the fiber or optic fails, the interface goes down and routing reacts at once. Hello timers are only a backstop.
  • Where a carrier circuit or media converter hides the failure, run BFD. Three missed 50 ms packets means about 150 ms detection. Supported minimum intervals vary by platform.

2. Precomputed alternates

  • Triangles, not squares. Each access switch connects to both distribution switches. The two paths are equal cost and both are in the forwarding table, so losing one is a local removal, not a recalculation. In a square the backup path has to be computed first.
  • EIGRP feasible successors and OSPF loop-free alternates (where supported) give a backup next hop in advance on non-ECMP topologies.

3. Limit the work

  • Summarize each distribution block toward the core. A failure inside the block changes nothing outside.
  • EIGRP stub on access switches keeps queries from spreading. OSPF areas keep LSA flooding local.
  • SPF throttle with a short initial wait so the first event is processed quickly.

4. Remove layer 2 from the path

Routed access takes STP and HSRP out of uplink failover. If you keep layer 2 access, use Rapid PVST+, a loop-free design and tuned FHRP timers.

5. Survive supervisor failures

NSF/SSO lets a dual-supervisor chassis keep forwarding while the standby takes over and neighbors help resynchronize. Aggressive hello or BFD timers toward that chassis can declare it dead before the switchover completes, so pick timers that let NSF work.

Example on IOS-XE

Cisco IOS
interface TenGigabitEthernet1/1/1
 no switchport
 ip address 10.1.255.0 255.255.255.254
 ip ospf network point-to-point
 bfd interval 50 min_rx 50 multiplier 3
!
router ospf 1
 bfd all-interfaces
 timers throttle spf 10 100 5000

Prove it

Send steady traffic (a traffic generator, or pings at a short interval) and pull a link, then a switch. Lost packets multiplied by the interval gives the real outage. Measure, do not assume.

Traps

  • Tuning timers everywhere before fixing the topology. Detection by loss of light and ECMP matter more.
  • Claiming sub-second convergence without having measured it.
How did you do?Book 3.4 Routing